The
RIEGL
LMS-Q120ii 2D - laser scanner provides accurate noncontact line scanning using a narrow infrared laser beam. The instrument makes use of the precise time-of-flight laser range measurement principle and fast line scanning by means of a highspeed opto-mechanical scan mechanism, providing fully linear, unidirectional and parallel scan lines.
The rugged overall system design makes the
RIEGL
LMS-Q120ii exceptionally well suited for installation in harsh industrial environments and is specially designed for long-term operation without the necessity of frequent maintenance. The instrument needs only one power supply and provides line scan data via the integrated TCP/IP Ethernet interface. The binary data stream can easily be post-processed by any user-designed software using the available software library.
Specifications
Features
Applications
Range Measurement Performance
Scanner Performance
Data Interfaces
Notes
Laser Product Classification
1
CLASS 1 Laser Product Classification according to IEC60825-1:1993+A1:1997+A2:2001
The following clause applies for instruments delivered into the United States:
Complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.
Input Voltage Range
18 to 32 VDC, 24 VDC nominal
Current Consumption
Approx. 2 A @ 24 VDC
Approx. 3.5 A with internal heater
Main Dimensions
180 x 374 mm (diameter x length)
With Protective Hood: 497 x 180 x 324 mm (L x W x H)
With Protective Housing & Hood: 589 x 190 x 339 mm (L x W x H)
Weight
approx. 7 kg
With Protective Hood: approx. 8 kg
With Protective Housing & Hood: approx. 13 kg
Temperature Range
-20ºC up to +50ºC (operation)/-20ºC up to +60ºC (storage)
Protection Class
IP64
Mounting
M8 steel thread inserts